FAULTFIXERDiagnose. Solve. Get Better.
FAULTBAY
✕ Close
Challenge #5 · vfds

Ready, But It Won't Run

A conveyor VFD shows READY on the display, no fault. The PLC gives the run command. The drive just sits there and the motor never moves.
① Run your checks
PLCrun cmdSAFETY STRINGenable / STOVFDMOTOR
② Make the call
③ Explain your reasoning optional

A strong answer covers:

  • What you did: checked the drive's fault status, the run command at the run input, and the safety enable / STO input.
  • The reason: READY with no fault and 24V at the run input means the drive and the command are fine; but the STO/enable read 0V, so the safety string is open.